After-sales Service: | Whole - Course Guidance |
---|---|
Warranty: | 5 Year |
Nature of Source Flow: | Active Inverter |
Phase: | Single |
Output Power: | 50 - 100W |
Certification: | CE, ROHS, ISO9001, CCC |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
MODEL | NM300-112 | NM300-124 | NM300-212 | NM300-224 | |
Output | AC Voltage | 100/110/120VAC | 220/230/240VAC | ||
Rated Power | 300W | ||||
Surge Power | Load 120~150%(3min.);600W(3sec;resistive) | ||||
Frequency | 50/60Hz ±3Hz | ||||
AC Regulation | ±5% | ±10% | |||
Waveform | Modified Sine Wave | ||||
Standard Receptacles | USA/British/Franch/Schuko /UK/Australia/Universal etc. optional | ||||
LED Indicator | Green for power on, red for faulty status | ||||
USB port | 5V 2.1A | ||||
Input | No Load Current Draw | ≤0.50A | ≤0.40A | ≤0.50A | ≤0.40A |
DC Voltage | 12VDC | 24VDC | 12VDC | 24VDC | |
Voltage Range | 10.5~15VDC | 21~30VDC | 10.5~15VDC | 21~30VDC | |
Efficiency(Typ.) | 89%~93% | ||||
Fuse | 50A×1 | 25A×1 | 50A×1 | 25A×1 | |
Protection | BAT. Low Alarm | 10.5±0.5VDC | 21±1.0VDC | 10.5±0.5VDC | 21±1.0VDC |
BAT. Low Shutdown | 10±0.5VDC | 20±1.0VDC | 10±0.5VDC | 20±1.0VDC | |
Over Load | Shut down output voltage , restart to recover | ||||
Over Voltage | 15.5±0.5VDC | 31±1.0VDC | 15.5±0.5VDC | 31±1.0VDC | |
Over Temperature | Shut down output voltage , recover automatically after temperature goes down | ||||
Output Short | Shut down output voltage , restart to recover | ||||
DC Input Reverse Polarity | By fuse | ||||
Earth Fault | Shut off o/p when the load has electrical leakage | ||||
Soft Start | Yes, 3-5 Seconds | ||||
Environment | Working Temp. | 0~+50ºC | |||
Working Humidity | 20~90%RH non-condensing | ||||
Storage Temp.& Humidity | -30~+70ºC,10~95%RH | ||||
Safety & EMC | Safety Standards | Certified458(only for "GFCI" receptacles) | Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013. | ||
Isolation Resistance | I/P-O/P:100M Ohms/500VDC | ||||
EMI Conduction & Radiation |
Certified FCC class A | Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3; | |||
EMS Immunity | ------ | Certified IEC61000-4-3, IEC61000-4-6 | |||
E-MARK | ------ | Certified ECE RIO.05:2014 | |||
Others | Dimension(L×W×H) | 190×102×57.5mm | |||
Packing | 1.15kg;16pcs/19.5kg/0.068m³ | ||||
Cooling | Load control fan or by thermal control fan | ||||
Application | Home and Office appliances, Portable Power Equipment, Vehicle,Yacht and Off-Gid Solar power systems…etc. |
In the course of quality control, machining fabrication commissioning and after sale service, Bestop complies with the international standard ISO9001 CE ROHs etc. The advanced production system and excellent quality control have enabled us to win the trust and support of our customers.
1.Q:Why choose us ?
Suppliers with verified business licenses